Krew Instruments is committed to providing safe and reliable laboratory equipment, and our Bio Safety Cabinet Class II type A2 is no exception. This advanced cabinet features HEPA / ULPA filtration, electronic sensors, and advanced airflow control to ensure a sterile environment and prevent contamination. With an ergonomic design for user comfort, our Bio Safety Cabinet is perfect for extended use in the laboratory. Our commitment to quality ensures that our equipment meets or exceeds industry standards. Trust Krew Instruments for reliable and effective laboratory solutions that provide the protection you need.
| Feature | Specification |
|---|---|
| Main Body Construction | G.I / MS Powder Coated / Complete Stainless Steel 304 |
| Internal Work Area | 1 mm (0.06") Stainless Steel 304 |
| Filter Type | HEPA / ULPA filter with 99.99% / 99.999% efficiency at 0.3 / 0.2 micron |
| Airflow | 70% Recirculated / 30% Exhaust |
| Working Aperture | 200 mm |
| Maximum Front Aperture | 400 mm |
| UV Tube Light | Germicidal UV Light (Programmable) |
| Sash Door | Motorized |
| Lighting Controls | Fluorescent & UV light ON/OFF switch |
| Ergonomic Design | 10° slope / tilt |
| Cleanliness Standard | Class 100 Environment |
| Blower-Motor Assembly | Dynamically balanced |
| Noise and Vibration | Low (65 dB) |
| Static Pressure Measurement | Pressure sensor |
| Air Velocity | 100 ft/min |
| Work Surface Illumination | Fluorescent tube light (1200 lux) |
| Average Inflow | 0.53 m/s (105 fpm) |
| Average Downflow | 0.35 m/s (70 fpm) |
| Control System | Microprocessor controlled real-time functions |
| Display | LCD screen |
| Monitoring | Downflow velocity, filter media life, static/negative pressure |
| Timer | UV lamp timer |
| Alarm | Incorrect position of front sash window (PLC/HMI only) |
| Electrical Outlets | Two 5/15 amp electrical duplex receptacles |
| Service Valves | Gas, Water, and Vacuum mounted on side wall |
| Wheels and Leveling Lugs (Optional) |
GI Model: PU solid wheels with plated brackets & metallic powder-coated leveling lugs SS Model: PU solid wheels with SS304 brackets & solid SS304 leveling lugs |
| Model No. | Working Size (in ft) | Size of HEPA Filter | No. of HEPA | No. of Blower | UV Light | Pre-filter | No. of Pre-filter |
|---|---|---|---|---|---|---|---|
| KBC-2A2 | 2 × 2 × 2 |
2' × 2' × 3" 12" × 14" × 3" |
2 | 2 | 1 | 0 | 0 |
| KBC-3A2 | 3 × 2 × 2 |
3' × 2' × 3" 12" × 18" × 3" |
2 | 2 | 2 | 0 | 0 |
| KBC-4A2 | 4 × 2 × 2 |
4' × 2' × 3" 24" × 14" × 3" |
2 | 3 | 3 | 0 | 0 |
| KBC-6A2 | 6 × 2 × 2 |
6' × 2' × 3" 12" × 14" × 3" |
2 | 4 | 4 | 0 | 0 |
Krew Instruments is a trusted source for customers because our Class II Type A2 Biosafety Cabinets are designed to solve safety issues that exist in many laboratories: airflow that is unreliable, containment that is weak, an obnoxious operational noise level, and filters that fail well before the manufactures stated useful life. Our cabinets are designed to eliminate these issues up front.
Krew Bio Safety Cabinet offer balanced and true protection for the operator, the environment, and sample. Our careful downflow and inflow controls, HEPA filtration, and non-turbulent work zone allow for sample integrity to remain intact even during long, sensitive procedures. An astute air handling system is employed to operate quietly, efficiently, and without inducing fatigue to the user. Our cabinets are built to endure and sophisticated alarms provide you with the knowledge that you're in control of the condition of your safety.
Krew Instruments brings you a biosafety cabinet that provides exceptional operator safety without compromise, provides reliable performance every day, and provides your team with the confidence to safely and efficiently conduct their work.