Krew Instrument’s with its expertise in the pharmaceutical industry, designs Plant Growth Chambers as per ICH, WHO, and I.S standards. These chambers provide a controlled environment for plant growth, allowing measurement of the effects of light, temperature, humidity, and atmospheric conditions on plant growth and function. With Krew’s Plant Growth Chambers, it is possible to create a precise environment for scientific research on plant biology, optimizing plant growth conditions in a controlled and reproducible manner.
| Feature | Specification |
|---|---|
| Micro Controller Timer | $99 \text{ Hours Programmable Micro Controller Based Cyclic Timer}$ for regulating illumination conditions. |
| Light Intensity | $300 \mu \text{moles/m}^2/\text{s}$ programmable through dimmable option. |
| Illumination | Fluorescent tubes for daylight effect in each compartment. |
| Refrigeration System | $\text{CFC Free}$ system. |
| Compressor | Hermetically sealed compressor with R $134\text{a}$ refrigerant. |
| Humidity System | Non-condensing steam injection system with water level arrangement and insulation to save heat energy. |
| Safety Features | 1. Float switch cuts off mains supply in case of low water level in boiler tank. |
| Validation Port | $50 \text{ mm}$ validation port with silicone rubber seal to insert sensors for validation. |
| Power Supply | $230 \text{ VAC single phase } 50 \text{ Hz}$ |
| Internal Arrangement | Adjustable tray height arrangement. |
| Mobility / Security | Castor wheels, MCB, and heavy-duty latch with lock & key. |
| Feature | KPC-10 | KPC-11 | KPC-12 | KPC-13 | KPC-14 | KPC-15 | KPC-16 | KPC-17 |
|---|---|---|---|---|---|---|---|---|
| Temperature Range | 10°C to 60°C | 10°C to 60°C | 10°C to 60°C | 10°C to 60°C | 10°C to 60°C | 10°C to 60°C | 10°C to 60°C | 10°C to 60°C |
| Temperature Accuracy | ±1°C | ±1°C | ±1°C | ±1°C | ±1°C | ±1°C | ±1°C | ±1°C |
| Temperature Uniformity | ±2°C | ±2°C | ±2°C | ±2°C | ±2°C | ±2°C | ±2°C | ±2°C |
| Temperature Resolution | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C |
| Humidity Range | 40% RH to 98% RH | 40% RH to 98% RH | 40% RH to 98% RH | 40% RH to 98% RH | 40% RH to 98% RH | 40% RH to 98% RH | 40% RH to 98% RH | 40% RH to 98% RH |
| Humidity Accuracy | ±2% RH | ±2% RH | ±2% RH | ±2% RH | ±2% RH | ±2% RH | ±2% RH | ±2% RH |
| Humidity Uniformity | ±3% RH | ±3% RH | ±3% RH | ±3% RH | ±3% RH | ±3% RH | ±3% RH | ±3% RH |
| Inner Size (W x D x H) in cm | 45 × 45 × 50 | 60 × 60 × 63 | 60 × 60 × 91 | 60 × 60 × 120 | 65 × 65 × 120 | 70 × 72 × 120 | 80 × 80 × 125 | 85 × 85 × 140 |
| Volume (Liters) | 100 | 225 | 325 | 425 | 500 | 600 | 800 | 1000 |
| No. of Trays | 2 | 3 | 3 | 4 | 7 | 7 | 8 | 8 |
Krew Instruments is selected by researchers because our plant growth chambers are specifically designed to solve the aggravations that cause unwanted interruptions during key experiments - variable lighting cycles, temperature variations, uneven humidity, and chambers that malfunction during long duration research. We create equipment that make your research stable, predictable, and truly repeatable.
Krew growth chambers provide exacting control of temperature, humidity, and light, guaranteeing that every plant enjoys the same environmental settings. Whether you are performing seed germination, tissue culture, or stress studies, the chamber's settings stay fixed even for very long-term studies.
When you use Krew Instruments you are getting reliable growth conditions, long-term stability, and a growth chamber that assists your study, not complicates it.
No. 4/1101, Niraj Park, Wayle Nagar, Gandhare Road, Kalyan West, Mumbai. Maharashtra 421301
Gala No. 004, B-Wing, Ground Floor Shree Ganesh Compound, Pawar Section Chikhloli MIDC Ambernath (East), Maharashtra 421506
+91 922 443 3419 / +91 859 123 9083
krewinstruments@gmail.com
info@krewinstruments.com